Abstract
A newly installed density diagnostic using CO2 laser interferometry and an Hα diagnostic using interference filters and photomultiplier tubes for the recently constructed sustained spheromak physics experiment (SSPX) are described. First diagnostic results of the Hα diagnostic were useful to understand the breakdown physics in the new SSPX experiments. Low-noise density data validates techniques to reduce vibration and electronic pickup. The data-processing electronics of the new interferometer can yield unambiguous density data that is equivalent to 16 fringe shifts. Density data is also critical to understand the particle source, and the J/ne parameter for SSPX.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.