Abstract
The purpose of the study was to determine denitrification rates during aeration tanks converting to the aero-mode of the nitri-denitrifier with the nitrate recycling. Studies were conducted on an experimental facility with wastewater and activated sludge from one of the sewage treatment facilities of the Udmurt Republic. At the beginning of the experiment, the activated sludge was under anoxic conditions (the mixture was mechanically mixed without aeration), while periodically the mixture was analyzed for nitrate content. Thus, the rate of denitrification during endogenous respiration was determined. Further, waste water was added to the sludge (anoxic conditions were preserved) - simulation of nitrate recycling. According to the results of experimental studies, the calculated denitrification rates were rds = 0.71 ± 0.04 mg N-NO3 / mg of active heterotrophic microorganisms per day on easily oxidizable substrate, on endogenous respiration rde = 0.12 ± 0.02 mg N-NO3 / mg of active heterotrophic microorganisms per day, on difficult oxidizable substrate rdp = 0.12 ± 0.01 mg N-NO3 / mg of active heterotrophic microorganisms per day.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.