Abstract

Acoustic emission (AE) source location provides a powerful tool for the engineer. Current methods, time of arrival (TOA) location and single sensor modal analysis location (SSMAL), are based on assumptions derived from a simplistic structure. In complex geometric structures these assumptions are incorrect. This paper describes a novel solution for AE source location in complicated geometric structures. “Delta T” source location utilises an artificial source; recording differences in times of arrival information from a number of locations, to improve source location. This method does not require knowledge of the sensor location or wavespeed. A 5-step description of the process is provided and practical results from an initial trial are presented. Results from the initial trial demonstrated a considerable improvement over the conventional TOA source location method, with a reduction in location error from 4.81% using the conventional TOA technique, to 1.77% using “Delta T” location.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.