Abstract

The pedicled transverse rectus abdominis myocutaneous (TRAM) flap is often used during breast reconstruction. After completely elevating the flap, a medial tunnel is created to connect the dissection area to the mastectomy defect. This tunnel should typically accommodate four of the surgeon’s fingers, although this may vary depending on flap volume. Wider tunneling facilitates flap delivery, but can damage the breast and inframammary fold. Therefore, we introduce a technique to move the flap easily and safely through a small tunnel. During breast reconstruction using a pedicled TRAM flap, a tunnel was made in the mastectomy defect along the meridian of the breast. This tunnel accommodated a width of three of the surgeon’s fingers (6 cm). After completely elevating the flap, it was inserted into a funnel with an inner surface made of polymeric vinyl and a hydrophilic coating. The flap was propelled into the mastectomy defect via the funnel. Our novel technique for pedicled TRAM flap delivery using a funnel was easy and safe, and it is deemed to be suitable for delivering a pedicled TRAM flap.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.