Abstract

Aqueous solutions of ethylene glycol and propylene glycol are used as heat transfer liquids in flat-plate solar collector systems. Both of the glycols are susceptible to thermal oxidative reactions, which produce organic acids with a resulting decrease in pH of the solutions. The effects of temperature, metals, common ions and oxidation conditions (aeration/deaeration) on the thermal stability of the glycol solutions were evaluated based on measuring changes in pH. Aerated heated glycol solutions produced acidic solutions within 3360 h (140 d) of testing, when in contact with either metallic aluminum or copper. Common ions (anions of the acid degradation products) were effective in suppressing decreases in pH, especially when aluminum was present.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.