Abstract

Pentoxifylline was subjected to various stress conditions and degradation profile was studied with conventional LCMS. Interestingly, under oxidative stress conditions the drug substance underwent distinct transformation to give rise to a single major degradation product. The structure of this product was elucidated using 1D, 2D NMR spectroscopy, high resolution mass spectrometry (Q-TOF LC/MS) and found to be a novel gem-dihydroperoxide, namely 1-(5,5-Bis-hydroperoxy-hexyl)-3,7-dimethyl-3,7-dihydro-purine-2,6-dione. An efficient stability indicating liquid chromatographic separation method was developed for pentoxifylline and its three degradation products (including two from base hydrolysis) using 1.8 μm, C18 reverse phase column and UHPLC. Baseline separation was achieved with a run time of 4 min. The analytical assay method was validated with respect to system suitability, specificity, linearity, range, precision, accuracy and robustness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.