Abstract

Background and purposeDelineation of organs at risk (OARs), such as the bladder, rectum and sigmoid, plays an important role in the delivery of optimal absorbed dose to the target owing to the steep gradient in high-dose rate brachytherapy (HDR-BT). In this work, we propose a deep convolutional neural network-based approach for fast and reproducible auto-contouring of OARs in HDR-BT. Materials and methodsImages of 113 patients with locally-advanced cervical cancer were utilized in this study. We used ResU-Net deep convolutional neural network architecture, which uses long and short skip connections to improve the feature extraction procedure and the accuracy of segmentation. Seventy-three patients chosen randomly were used for training, 10 patients for validation, and 30 patients for testing. Well established quantitative metrics, such as Dice similarity coefficient (DSC), Hausdorff distance (HD), and average symmetric surface distance (ASSD), were used for evaluation. ResultsThe DSC values for the test dataset were 95.7 ± 3.7%, 96.6 ± 1.5% and 92.2 ± 3.3% for the bladder, rectum, and sigmoid, respectively. The HD values (mm) were 4.05 ± 5.17, 1.96 ± 2.19 and 3.15 ± 2.03 for the bladder, rectum, and sigmoid, respectively. The ASSDs were 1.04 ± 0.97, 0.45 ± 0.09 and 0.79 ± 0.25 for the bladder, rectum, and sigmoid, respectively. ConclusionThe proposed deep convolutional neural network model achieved a good agreement between the predicted and manually defined contours of OARs, thus improving the reproducibility of contouring in brachytherapy workflow.