Abstract

Deep learning reconstruction (DLR) introduces deep convolutional neural networks into the reconstruction flow. We examined the clinical applicability of drip-infusion cholangiography (DIC) acquired on an ultra-high-resolution CT (U-HRCT) scanner reconstructed with DLR in comparison to hybrid and model-based iterative reconstruction (hybrid-IR, MBIR). This retrospective, single-institution study included 30 patients seen between January 2018 and November 2019. A radiologist recorded the standard deviation of attenuation in the paraspinal muscle as the image noise and calculated the contrast-to-noise ratio (CNR) in the common bile duct. The overall visual image quality of the bile duct on thick-slab maximum intensity projections was assessed by two other radiologists and graded on a 5-point confidence scale ranging from 1 (not delineated) to 5 (clearly delineated). The difference among hybrid-IR, MBIR, and DLR images was compared. The image noise was significantly lower on DLR than hybrid-IR and MBIR images and the CNR and the overall visual image quality of the bile duct were significantly higher on DLR than on hybrid-IR and MBIR images (all: p < 0.001). DLR resulted in significant quantitative and qualitative improvement of DIC acquired with U-HRCT.