Abstract
Ultraviolet (UV) detectors based on surface acoustic wave (SAW) technology offer unique advantages of remote or wireless operation capability with a potential of zero power consumption. Frequency shift of SAW devices induced by UV irradiation is mainly caused by acoustoelectric and thermal effects, although mass-loading and photo-capacitive effect might also have minor influences. Currently the individual contribution from either acoustoelectric effect or thermal effect for UV sensing has not been thoroughly studied. In this work, we systematically investigated the contribution of acoustoelectric and thermal effects at different UV light intensities based on a LiNbO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> SAW device with its wavelength of 20 μm, and decoupled their individual contributions to the overall ultraviolet responses for acoustic wave sensing. We found that for the LiNbO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> SAW device without any surface treatment, the frequency shift was mainly caused by the thermal accumulation induced by UV radiation. Whereas for the LiNbO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> SAW devices coated with zinc oxide nanowires (ZnO NWs), the frequency shift is caused by the combined acoustoelectric and thermal effects. We found that the frequency shift caused by acoustic electric effect is dominant at a low UV intensity (< 30 mW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ). Whereas with the UV light intensity larger than 90 mW/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , the photogenerated carriers generated by ZnO NWs became saturated, and then the thermal effect became dominant. This study clarifies the nature of individual influences of these two factors on the dominant mechanisms of the SAW based UV sensing at different conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.