Abstract

RSI (resonant snubber inverter) is able to be raised power conversion efficiency by applying the adjustable dead-time control. However, when the adjustable dead-time control is applied to RSI, output current THD (total harmonics distortion) increases. As a solution of this problem, a dead-time compensation scheme was applied to adjustable dead-time controlled single-phase RSI. In addition, the effectiveness of the control scheme was verified. However, a dead-time compensation scheme was applied only to single-phase. Thus, in this paper, dead-time compensation scheme was applied to adjustable dead-time controlled three-phase RSI, and the effectiveness of the control scheme was verified through simulations and experiments. As result of simulations and experiments, output current THD was able to be decreased.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.