Abstract

The auxiliary resonant snubber inverter (RSI) has demonstrated superiority in reduction of switching losses and dv/dt. It was found that the overall inverter system efficiency might not be improved if the resonant current was not controlled in accordance with the load current. This paper proposes an improved control scheme to minimize the operation of auxiliary circuit for efficiency improvement. The principle of this control scheme is to vary the resonant current with variable timing control based on the load current magnitude and to disable the auxiliary circuit operation when diode freewheeling occurs after switching. To illustrate the operation of this control scheme, this paper compares the switching characteristics and inverter power loss of hard-switching inverter, RSI with fixed-timing and variable-timing control and RSI with the proposed control scheme. Experimental results fully agree with the analyses and prove that the proposed control scheme is suitable for RSI to achieve better operating conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.