Abstract

Environmental bacteria strains are known to be more resistant but studies on UV-LEDs are scarce, especially for Clostridium perfringens and Enterococcus faecalis. UV-LEDs of different wavelengths (268 nm, 279 nm and 307 nm) have been used for treating real wastewater from the effluent of the municipal plant in Linares (Spain), with real organic matter content, for E. coli, Enterococcus faecalis and Clostridium perfringens disinfection.Experimental results demonstrate that 268 nm was the most effective wavelength for inactivation of the three different bacteria strains: E. coli showed an inactivation rate of 0.561 at 268 nm vs. 0.245 at 279 nm and 0.0029 for 307 nm; E. faecalis inactivation rate was 0.313 at 268 nm, 0.231 at 279 nm and 0.0023 at 307 nm; and C. perfringens inactivation rate was 0.084 at 268 nm, 0.033 at 279 nm and 6.9e-4 at 307 nm. In general, 307 nm wavelength showed a significantly lower inactivation rate so it would not be recommended for practical applications. C. Perfringens required higher UV doses and longer times to achieve complete inactivation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.