Abstract

The aim of this study is to verify the reciprocity law in the wastewater disinfection process using UV light. The optical power UV-LEDs used were 1.6 mW and 50 mW, and the wavelengths were 265 nm and 275 nm. E. coli, Enterococcus faecalis, and Clostridium perfringens were the three microorganisms analysed in the study. The results showed lower inactivation rates around 0.063–0.065 cm2/mJ for 265 nm and 0.047–0.049 cm2/mJ for 275 nm for the Clostridium perfringens compared with the other two bacteria. For E. coli and Enterococcus faecalis, the inactivation rate was almost identical; 0.28 and 0.21 cm2/mJ, respectively, using 265 nm wavelength. There was a slightly better inactivation performance using the medium-power 275 nm UV-LEDs of 0.39 cm2/mJ and 0.29 cm2/mJ for E. coli and Enterococcus faecalis, respectively, and 0.33 cm2/mJ and 0.26 cm2/mJ using the low-power 275 nm UV-LEDs. The analysed data justify the reciprocity law for UV-LEDs disinfection using 265 nm and 275 nm UV-LEDs with two optical powers of 1.6 mW and 50 mW.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.