Abstract
This study investigates the DC regulation of a DC-DC buck converter operating with pulse width modulation (PWM), taking into account the internal resistance of the coil and the on-resistance of the switching device. The effect of these parameters on the input/output disturbances is analyzed in continuous-conduction mode under constant frequency voltage mode control. The study also explores the effect on loop gain using the IRU3037 8-pin IC synchronous PWM controlled buck converter. The transfer function of the IRU3037 IC is derived from datasheet values using state-space averaging and AC small signal methods. A Type II compensator is then designed based on the derived transfer function. In addition, the step response characteristics of the open-loop and closed-loop circuits are investigated by time domain analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.