Abstract
The daylighting performance of the Pacific Museum of Flight in Seathle, WA, has been analyzed using the DOE-2.1C building energy simulation program. The main exhibit areas of this museum are enclosed on three sides by glass walls and the 4500-m 2 roof is completely glazed. Because of the large glass areas, a detailed thermal simulation of the building was carried out during its design phase in order to select glazing parameters that would avoid excessive summer solar heat gain, reduce winter heat loss and, at the same time, provide enough natural light of significantly reduce electric lighting loads. Glazing choices considered included conventional glass, heat mirror, and glass with a low-emissivity coating. On/off, stepped and continuous dimming lighting control systems were analyzed. Daylighting was found to be very effective in reducing annual electric lighting load, peak electrical demand, and the overall annual energy consumption.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.