Abstract

ABSTRACT This study investigated twenty-two (22) state elementary schools, regarding daylight annual illuminance in the classrooms, using climate-based daylight modelling (CBDM) metrics. This is due to the missing information on the annual daylight performance inside the classroom in Indonesia. Over 250 classrooms were assessed using Rhinoceros and Grasshopper computational platforms. Furthermore, Daysim simulation engine was employed through the advantage of Ladybug tools to connect and automate the simulation workflow parametrically. Since there were no prior studies using CBDM metrics for daylight assessment of classrooms in the Indonesian context, the illuminance range from 250 to 750 lux was taken as the target for the annual useful daylight illuminance (UDI), as suggested in the Indonesian daylighting standard. Result shows 35 classrooms under the good daylight performance, 171 classrooms in sufficient category and 50 others under unsatisfactory of annual illuminance. The most sensitive contributors are both corridor and back shading depth with Spearman correlation of -0.70 and -0.76 respectively. The strong sensitive variables both has p-values lower than 0.05 which indicates statistically significant for the model.