Abstract

Evidence is provided to support the view that 68%–76% of the energy required to produce domestic hot water may be extracted from the ground which serves as a renewable energy resource. The case refers to a 345 m2 research house located in Oak Ridge, Tennessee, 36.01°N 84.26°W in a mixed-humid climate with HDD of 2218 °C-days (3993 °F-days) and CDD of 723 °C-days (1301 °F-days). The house is operated under simulated occupancy conditions in which the hot water use protocol is based on the Building America Research Benchmark Definition which captures the water consumption lifestyles of the average family in the United States. The 5.3 kW (1.5-ton) water-to-water ground source heat pump (WW-GSHP) shared the same vertical bore with a separate 7.56 KW water-to-air ground source heat pump for space conditioning the same house. Energy and exergy analysis of data collected continuously over a twelve month period provide performance metrics and sources of inherent systemic inefficiencies. Data and analyses are vital to better understand how WW-GSHPs may be further improved to enable the ground to be used as a practical renewable energy resource.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.