Abstract

L-shaped concrete filled steel tube (L-CFST) columns are used frequently in civil engineering, and the concrete damage inside the L-CFST column is difficult to monitor. This research aims to develop a new method to monitor the internal concrete damage in the L-CFST column by using embedded piezoceramic smart aggregates (SAs) under low frequency cyclic loading. The SA enabled active method is used to monitor the concrete damages near the bottom of the L-CFST columns, and the wavelet packet analysis is used to establish a damage index, which is used to analyze the acquired data. During the experiment, three L-CFST columns with different wall thickness of the steel tube were tested. The experimental results find that the structural damage indices under the low-frequency cyclic loading are basically consistent with the results of the hysteretic curves and the skeleton curve of the specimens, and are in good agreement with the experimental phenomena. We conclude that the use of smart aggregate can directly and clearly reflect the damage process of the concrete core, demonstrating the feasibility of using piezoceramic smart aggregates to monitor the internal concrete damage of the L-CFST column.

Highlights

  • In recent years, high performance and multi-functional materials and structures have received much attention [1,2,3,4]

  • We conclude that the use of smart aggregate can directly and clearly reflect the damage process of the concrete core, demonstrating the feasibility of using piezoceramic smart aggregates to monitor the internal concrete damage of the L-shaped concrete filled steel tube (L-concrete-filled steel tube (CFST)) column

  • L-shaped concrete-filled steel tube (L-CFST) columns are increasingly used because of their architectural appearance and space saving at structural corners

Read more

Summary

Introduction

High performance and multi-functional materials and structures have received much attention [1,2,3,4]. Concrete-filled steel tube (CFST) columns, which have characteristics such as high stiffness and strength, large energy absorption capacity, and high ductility, are widely used in the construction of buildings. L-shaped concrete-filled steel tube (L-CFST) columns are increasingly used because of their architectural appearance and space saving at structural corners. CFST structures are subject to damages under the repeated action of seismic loads. Internal structural damages will continue to accumulate with the cyclic action of loads and the structure will fail as the damages increase to a certain degree. The damage of concrete inside the steel tube will significantly reduce the bearing capacity and ductility of the CFST, the internal concrete damage cannot be directly observed. It is very important to monitor the internal concrete damage of the structure

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call