Abstract

After long-term storage, plastic sealing devices must have good performance when installed on the whole machine. Identifying the risk of failure mode and taking preventive measures before failure can effectively improve storage reliability. To ensure the quality of military products, this paper studies the storage failure modes of plastic sealed micro-electronic devices, and uses the method of FMECA to calculate the damage degree of each failure mode and determine the key failure modes. The case analysis shows that the damage degree of failure mode is ranked as external lead corrosion, aging of packaging material, chip corrosion and bonding ball corrosion. The evaluation result accords with the actual situation of the method. The improved FMECA model can better deal with the relative importance of risk factors, improve the accuracy of risk ranking, and quantify risks more reasonably.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.