Abstract

BackgroundThe integration of positron emission tomography (PET) and magnetic resonance imaging (MRI) holds promise for advancing diagnostic imaging capabilities. The METRICS project aims to develop cyclotron-driven production of 52Mn for PET/MRI imaging.ResultsUsing the 52Cr(p,n)52Mn reaction, we designed chromium metal targets via Spark Plasma Sintering and developed a separation procedure for isolating 52Mn. Labeling tests were conducted with traditional chelators (i.e. S-2-(4-Isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane tetraacetic acid) and the 1.4-dioxa-8-azaspiro[4.5]decane-8- carbodithioate ligand to produce radioactive complexes suitable for PET/MRI applications. Our methodology yielded high-quality 52Mn suitable for PET radiopharmaceuticals and PET/MRI imaging. Preliminary studies on phantom imaging using microPET and clinical MRI demonstrated the efficacy of our approach.ConclusionsThe developed technology offers a promising avenue for producing 52Mn and enhancing PET/MRI imaging capabilities. Further in vivo investigations are warranted to evaluate the potential advantages of this hybrid imaging technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.