Abstract

A selective and simple method for the determination of iodate (IO3-) and bromate (BrO3-) by microcolumn ion chromatography (IC) is presented. In this study, IO3- and BrO3- were determined as IBr2- and tribromide (Br3-), respectively, via a postcolumn reaction with bromide (Br) under acidic conditions with the aid of alpha-cyclodextrin (alpha-CD) in microcolumn IC. IO3- and BrO3- were selectively detected by the present method at a wavelength of 253 or 265 nm. The present system achieved good selectivity for IO3- and BrO3- as well as good repeatability under suitable conditions. Precolumn enrichment improved the detection limit, and allowed the determination of BrO3- in bottled water as low as sub microg L(-1) level in microcolumn IC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.