Abstract
Holes 20 Å in diameter and fine lines 20 Å wide can be cut in the metal-β-aluminas using the 10 Å electron beam of the Vacuum Generators, HB5 scanning transmission electron microscope. The minimum current density required for cutting was 103 amp/cm2. Electron energies of 40,60,80,100 keV were used.This technique has higher resolution than current lithography methods and is direct, requiring no chemical development. The width of isolated lines made on solid substrates is currently about .1μm (Ahmed and McMahon, 1981) and .03μm (Jackel et al., 1980). M. Isaacson and A. Murry have carried out electron beam writing on NaCl crystals supported on a carbon film on the scale we report here.In our case uniform 20Å holes and lines can be cut through self-supporting 1000A thick slabs of sodium-β-alumina to provide very high electron contrast. Once cut, the β-aluminas are stable and will tolerate exposure to air without degradation of the electron cut patterns. They may be used directly as masks (eg. for ion implantation). We believe they could be cut on the substrate with no damage to the underlying material.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Proceedings, annual meeting, Electron Microscopy Society of America
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.