Abstract

The present current control method in doubly fed induction generator cannot realize the segmented grid-connected current control, it’s hard to effectively control the current in doubly fed induction generator. Therefore, a current control method in doubly fed induction generator under low switching frequency is proposed in this paper. Which means to build a mathematical model of the doubly fed induction generator under low switching frequency to analyze the parameters of doubly fed induction generator filter. Then the parameter values of the filter can be obtained. The current in generator can be predicted by adopting the double-sampling predict method. And the current control in generator can be improved according to dead beat control. Then the on-line identification of current parameters by least square method is needed to finish the current control method in doubly fed induction generator under low switching frequency. The experimental results show that the proposed method realized the segmented grid-connected current control in doubly fed induction generator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.