Abstract
The New Mexico Environment Department (NMED) requires a Corrective Measures Evaluation to evaluate potential remedial alternatives for contaminants of concern (COCs) in groundwater at Sandia National Laboratories New Mexico (SNUNM) Technical Area (TA)-V. These COCs consist of trichloroethene, tetrachloroethene, and nitrate. This document presents the current conceptual model of groundwater flow and transport at TA-V that will provide the basis for a technically defensible evaluation. Characterization is defined by nine requirement areas that were identified in the NMED Compliance Order on Consent. These characterization requirement areas consist of geohydrologic characteristics that control the subsurface distribution and transport of contaminants. This conceptual model document summarizes the regional geohydrologic setting of SNUNM TA-V. The document also presents a summary of site-specific geohydrologic data and integrates these data into the current conceptual model of flow and contaminant transport. This summary includes characterization of the local geologic framework; characterization of hydrologic conditions at TA-V, including recharge, hydraulics of vadose-zone and aquifer flow, and the aquifer field of flow as it pertains to downgradient receptors. The summary also discusses characterization of contaminant transport in the subsurface, including discussion about source term inventory, release, and contaminant distribution and transport in the vadose zone and aquifer.