Abstract

Two types of low cycle fatigue tests were conducted along two principal orthotropic directions of an orthotropic Al-6061-T6 plate in strain control at room temperature: (1) reference fatigue tests under three loading conditions: push-pull, torsion, and combined push-pull/torsion in-phase; (2) sequential fatigue tests in which different sequences of push-pull and torsion were performed. Fatigue cracking behavior was observed during all of the fatigue tests. Shear cracking dominated the damage of the material. Anisotropic constitutive relations of the material were used in the evaluation of several multiaxial fatigue damage models. The predictive capabilities of these models were assessed based on the results of reference fatigue tests. The damage accumulation behavior of the material was found to depend on the sequence of the loading mode. For the sequence of torsion then push-pull, the damage summation was greater than unity. However, for the sequence of push-pull then torsion, the damage accumulation was near unity as predicted by the linear damage rule. A nonlinear damage accumulation rule could represent the results of the sequential fatigue tests.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.