Abstract

Today in many cases ultrasonic testing machines with a frequency of f ≈ 20 kHz are used for investigations of the fatigue behaviour up to the very high cycle regime (VHCF-regime). A question that arises is if the results of these high frequency fatigue tests are comparable to conventional fatigue tests. This paper compares the fatigue behaviour of a quenched and tempered steel 50CrMo4 in two different tempered conditions investigated at low frequencies (f ≤ 400 Hz) on a servohydraulic testing machine and at a high frequency (f ≈ 20 kHz) on an ultrasonic fatigue testing machine. Effects which can occur because of the different testing techniques and testing frequencies are investigated. A concept is derived to describe the frequency effect caused by the strain rate. The estimations are compared with results of the fatigue tests.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call