Abstract
ObjectivesTo investigate the usefulness of minimal ablative margin (MAM) control by intra-procedural contrast-enhanced CT (CECT) in microwave ablation (MWA) of liver tumors.MethodsA total of 334 consecutive liver tumors (240 hepatocellular carcinomas [HCCs] and 94 colorectal liver metastases [CRLMs]) in 172 patients treated with percutaneous MWA were retrospectively included. MAM of each tumor was assessed after expected ablation completion using intra-procedural CECT, allowing within-session additional ablation to any potentially insufficient margin. On immediate post-MWA MRI, complete ablation coverage of tumor and final MAM status were determined. The cumulative local tumor progression (LTP) rate was estimated by using the Kaplan-Meier method. To identify predictors of LTP, Cox regression analysis with a shared frailty model was performed.ResultsIntra-procedural CECT findings prompted additional ablation in 18.9% (63/334) of tumors. Final complete ablation coverage of tumor and sufficient MAM were determined by MRI to be achieved in 99.4% (332/334) and 77.5% (259/334), and their estimated 6-month, 1-year, and 2-year LTP rates were 3.2%, 7.5%, and 12.9%; and 1.0%, 2.1%, and 6.9%, respectively. Insufficient MAM on post-MWA MRI, perivascular tumor location, and tumor size (cm) were independent risk factors for LTP (hazard ratio = 14.4, 6.0, and 1.1, p < 0.001, p = 0.003, and p = 0.011, respectively), while subcapsular location and histology (HCC vs CRLM) were not.ConclusionsIn MWA of liver tumors, intra-procedural CECT monitoring of minimal ablative margin facilitates identification of potentially suboptimal margins and guides immediate additional intra-session ablation to maximize rates of margin-sufficient ablations, the latter being a highly predictive marker for excellent long-term local tumor control.Key Points• In MWA of liver tumors, intra-procedural CECT can identify potentially suboptimal minimal ablative margin, leading to immediate additional ablation in a single treatment session.• Achieving a finally sufficient ablative margin through the MWA with intra-procedural CECT monitoring of minimal ablative margin results in excellent local tumor control.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.