Abstract
To compare microvascular flow imaging (MVFI) and power Doppler ultrasonography imaging (PDUS) for detecting intratumoral vascularity in recurrent thyroid cancer both before and after radiofrequency ablation (RFA). This retrospective study included 80 patients (age, 57 ± 12 years; 54 women) with 110 recurrent tumors who underwent RFA between January 2021 and June 2023. A total of 151 PDUS and MVFI image sets were analyzed (85 pre-RFA, 66 post-RFA). Two readers assessed vascularity on the images using a four-point scale with a 2-week interval between PDUS and MVFI to estimate inter-reader agreement. Intra-reader agreement was determined by reinterpreting images in reverse order (MVFI-PDUS) after a 1-month gap. Additionally, diagnostic performance for identifying viable tumors after RFA was assessed in 44 lesions using thyroid-protocol CT as a reference standard. MVFI demonstrated higher vascular grades than PDUS, both before (reader 1: 3.04 ± 1.15 vs. 1.93 ± 1.07, p < 0.001; reader 2: 3.20 ± 0.96 vs. 2.12 ± 1.07, p < 0.001) and after RFA (reader 1: 2.44 ± 1.28 vs. 1.67 ± 1.06, p < 0.001; reader 2: 2.62 ± 1.23 vs. 1.83 ± 0.99, p < 0.001). Inter-reader agreement was substantial (κ = 0.743) and intra-reader agreement was almost perfect (κ = 0.840). MVFI showed higher sensitivity (81.5%-88.9%) and accuracy (84.1%-86.4%) than PDUS (sensitivity: 51.9%, p < 0.01; accuracy: 63.6-70.5%, p < 0.04), without sacrificing specificity. MVFI was superior to PDUS for assessing intratumoral vascularity and showed good inter- and intra-reader agreement, highlighting its clinical value for assessing pre-RFA vascularity and accurately identifying post-RFA viable tumors in recurrent thyroid cancer. Microvascular flow imaging (MVFI) is superior to power-Doppler US for assessing intratumoral vascularity; therefore, MVFI can be a valuable tool for assessing vascularity before radiofrequency ablation (RFA) and for identifying viable tumors after RFA in patients with recurrent thyroid cancer. The value of microvascular flow imaging (MVFI) for evaluating intratumoral vascularity is unexplored. MVFI demonstrated higher vascular grades than power Doppler US before and after ablation. Microvascular flow imaging showed higher sensitivity and accuracy than power Doppler US without sacrificing specificity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.