Abstract

The 8 wt. % yttria stabilized zirconia top coat (TC) and the CoNiCrAlY bond coat (BC) were sprayed onto the surface of newly developed fine-grained cast polycrystalline nickel-based superalloy Inconel 713LC by means of atmospheric plasma spraying (APS). As-prepared samples were isothermally exposed at the temperature of 1050 °C for 200 hours in an ambient atmosphere. Structural changes in the thermal barrier coatings (TBC) system after thermal exposure were studied by means of scanning electron microscope equipped with an energy dispersive microanalyzer. Critical weak points were identified on both the substrate-bond coat and bond coat-top coat interfaces.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.