Abstract

Both longitudinal and transverse coupling impedance of a fast extraction kicker magnet has been measured for the design and development of beam extraction in the Spallation Neutron Source accumulator ring. The conventional wire method with improved techniques is employed in the bench test. The experimental result is explained by and compared with a newly developed resonant circuit model. The impact of the measurement on the fast extraction kicker magnet design is discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.