Abstract

Both longitudinal and transverse coupling impedance of a fast extraction kicker magnet has been measured for the design and development of beam extraction in the Spallation Neutron Source accumulator ring. The conventional wire method with improved techniques is employed in the bench test. The experimental result is explained by and compared with a newly developed resonant circuit model. The impact of the measurement on the fast extraction kicker magnet design is discussed.