Abstract

Pitting corrosion of austenitic stainless steel weld joints served in a hydrocracking unit for 6 years was examined. The microstructure of weld metal (WM) and fusion line (FL) was austenite and ferrite. After the immersion test, many pits were observed on the FL, whereas few pits were observed on the heat-affected zone (HAZ). Pits were microscopically initiated at ferrite/austenite boundaries. Hydrogen concentrations at FL and WM were higher than those of HAZ, and hydrogen segregation occurred at ferrite/austenite boundaries, which was consistent with the pit position. Hydrogen enrichment conditions varied under different microstructures, which induced the difference in pitting susceptibility.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.