Abstract

A newly developed γ-ray computed tomography scanner was implemented to study liquid flow distribution in a 30.48-cm-diameter column packed with corrugated structure using countercurrent air–water flow. Validation experiments confirm that spatial resolution of ∼2.5 mm can be achieved by the new CT unit. Within the gas (0–10 cm/s superficial velocity) and liquid (0.6–2.5 cm/s superficial velocity) flow ranges investigated, a good liquid distribution was observed at all conditions, as manifested by uniformity factor in excess of 70%. The liquid saturation increases with increasing superficial liquid velocity as well as down the column height. Within the conditions studied, the effect of gas velocity was, in general, found to be minimal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.