Abstract

Steady state counter-current flow limitation (CCFL) experiments were conducted in a 1:3 scaled flat model of the hot leg and part of the steam generator inlet chamber of a German Konvoi pressurized water reactor. The experiments include air-water tests at 1 and 2bar as well as steam-water tests at 10, 25 and 50bar. Flooding characteristics are obtained in dependency on the dimensionless gas and liquid flow rates (Wallis-parameter). They showed a slight, but clear dependency on pressure – with increasing pressure more liquid can flow in counter-current to the gas in case of partial CCFL. Also the dimensionless gas flow rate for zero penetration slightly increases with pressure. Beside the flooding characteristics also slug frequencies were analyses basing on pressure measurements along the horizontal part of the test section. Finally, comprehensive video material was obtained which is suited for extracting quantitative data on the local flow structure. This can contribute to the further CFD-code development and validation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.