Abstract
A type 316 stainless steel thermal convection loop with type 316 stainless steel coupons and a Fe-9Cr-1Mo steel loop containing Fe-12Cr-1MoVW steel specimens circulated molten Pb-17 at% Li at a maximum temperature of 500°C. Specimens were exposed for more than 6000 h. Mass loss and surface characterization data were compared for these two alloys. At any particular exposure time, the corrosion of type 316 stainless steel by Pb-17 at% Li was more severe, and of a different type than that of similarly exposed Fe-12Cr-1MoVW steel. The austenitic alloy suffered nonuniform penetration and dissolution by the lead-lithium, whereas the Fe-12Cr-1MoVW steel tended to be more uniformly corroded. The presence of a ferritic layer on the type 316 stainless steel, and its susceptibility to spalling during specimen cleaning, were shown to be important in evaluating the data for this steel and in comparing corrosion losses for the two types of alloys. A model for the nonuniform penetration of type 316 stainless steel by Pb-17 at% Li was suggested.
Submitted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.