Abstract

This investigation was primarily aimed to examine the in-service failure of an economizer tube. Apart from preliminary visual examination, the analysis for the probable cause of failure was supplemented with radiographic examination, metallographic examination, energy dispersive spectroscopy, and scanning electron microscopy. Finally, it was concluded that there was seepage of water from an unusual blowhole-like through-thickness hole in the weld region of the economizer tube. This water vaporized and reacted with the flue gases and caused localized corrosion and led to the ultimate failure of the tube.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.