Abstract

PurposeThis paper aims to analyze the high temperature (200°C) corrosion behavior of 2205 duplex stainless steel in acidizing stimulation solution containing hydrochloric acid (HCl) and acetic acid.Design/methodology/approachThe corrosion rate of 2205 duplex stainless steel in all kinds of acid solutions was calculated through immersion tests and electrochemical test. The corrosion product composition is analyzed by X-ray diffraction analysis. The element composition and element distribution before and after corrosion were analyzed by an X-ray energy spectrometer. The corrosion morphology of the steel surface was observed by a scanning electron microscope. Both static and dynamic corrosion experiments were carried out at 200°C.FindingsThe results show that 2205 duplex stainless steel has excellent corrosion resistance in low to high concentration acetic acid solutions, but increasing the concentration of Cl− in acetic acid solution will accelerate the corrosion rate. Low concentration HCl solution can cause serious corrosion to 2205 duplex stainless steel. The system of HCl and acetic acid will produce a synergistic effect on corrosion of 2205 duplex stainless steel and accelerate the corrosion. Sb2O3 is a good corrosion inhibitor synergist for high-temperature acidizing stimulation solution.Originality/valueThe amount of HCl that is used in acidizing stimulation is usually determined by the dissolution effect of the acid on the rocks, but for ultra-high-temperature reservoirs, the amount of HCl should be based on reducing the corrosion of oil and gas wells.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call