Abstract

ABSTRACTThe present experimental investigation is focused on the study of heat transfer and pressure drop of heat exchanger tube fitted with dimpled ribs on the inner wall. The effect of geometrical parameters, predominantly the streamwise spacing, spanwise spacing, and dimpled depth to print diameter has been investigated. The heat exchanger tube has streamwise spacing () in range of 15–35, spanwise spacing () in range of 15–35, ratio of dimpled depth to print diameter () of 0.5–1.5, and Reynolds number () ranges from 5,000 to 27,000. Experimental results show that the heat transfer and thermal hydraulic performance enhances by 4.19 times and 2.53 times, respectively, for of of 15, of 15, and of 1.0. The experimental data collected are utilized for the development of the statistical correlations for and for selected values of roughness parameters and flow Reynolds number.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.