In geotechnical engineering, the Standard Penetration Test (SPT-N value) is often used as an in-situ test. The Cone Penetration Test (CPT) is based on design and cone resistance (qc) and is becoming increasingly widespread. However, there is also a need for a SPT-CPT correlation association that can be used in the basic design. In this study, the values of the SPT-CPT tests applied to the ground were compared and tried to generate a certain statistical data. SPT and CPT experiments were performed side by side to determine the soil properties. Formulas have been developed using various statistical methods and correlation coefficients have been established between the data obtained for “high-medium-low plastic clay” and “sand and sandy clayey soils”. The obtained data were compared with the studies in the literature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.