Abstract

The correlation of PCDD/PCDF levels with the CO emissions in a full-scale municipal waste incinerator was assessed during a four-week measurement effort. PCDD/PCDF concentrations in fly ashes-containing more than 99% of the total PCDD/PCDF burden of the fluidized bed incinerator (FBI)-were measured and compared with the emitted CO concentrations. The CO concentration during the sampling time showed no significant correlation to the PCDD/ PCDF amount in fly ash (R2 = 0.078). However, a comparison of the time integrated CO concentration several hours before sampling lead to a correlation with the PCDD/PCDF burden. Maximum correlation was found for the time integrated CO values of 3 and 4 h before sampling (R2 = 0.467 and R2 = 0.457 respectively). This indicates a memory effect in the high temperature cooling section of several hours. Possible mechanisms leading to the memory effect are discussed. The correlation of PCDD/PCDF with CO concentration demonstrate that the combustion conditions play an important role for PCDD/PCDF formation in FBIs. However the variability in the correlation of CO to PCDD/PCDF levels show that other factors have a significant influence on PCDD/PCDF formation.