Abstract
Extremely preterm infants (gestational age ≤ 28 weeks) often require EndoTracheal Tube-Invasive Mechanical Ventilation (ETT-IMV) to survive. Clinicians wean infants off ETT-IMV as early as possible using their judgment and clinical information. However, assessment of extubation readiness is not accurate since 20 to 40% of preterm infants fail extubation. We extended our work in automated prediction of extubation readiness by examining correlations of automated cardiorespiratory features to clinical parameters in successfully extubated infants. Only a few features, mainly those related to variability of breathing synchrony, had any consistent correlation with clinical parameters, namely gestational age, day of life at extubation, and bicarbonate. We conclude that the automated cardiorespiratory features likely provide different information additional to clinical practice.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.