Abstract
Unfortunately, in the above article <xref ref-type="bibr" rid="ref1" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">[1]</xref> , a minor mathematical error needs to be corrected. <xref ref-type="disp-formula" rid="deqn1" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Equation (1)</xref> corresponds to the flow velocity in a Z-configuration meter, whereas the meter shown schematically in Fig. 1 is a V-configuration meter. The difference between the two equations is that the equation for the V-configuration meter has an extra factor of two in the denominator. This correction does not affect the remainder of the article, as the correct equation was used during data processing.