Abstract
Background: It has been shown that coronary flow velocity reserve (CFVR) measurement by transthoracic Doppler echocardiography (TTDE) during dobutamine (DOB) provocation provides a more accurate functional evaluation of myocardial bridging (MB) compared to adenosine. However; the cut-off value of CFVR during DOB for identification of MB associated with myocardial ischemia has not been fully clarified. Purpose: This prospective study aimed to determine the cut-off value of TTDE-CFVR during DOB in patients with isolated-MB, as compared with stress-induced wall motion abnormalities (VMA) during exercise stress-echocardiography (SE) as reference. Methods: Eighty-one symptomatic patients (55 males [68%], mean age 56 ± 10 years; range: 27–74 years) with the existence of isolated-MB on the left anterior descending artery (LAD) and systolic MB-compression ≥50% diameter stenosis (DS) were eligible to participate in the study. Each patient underwent treadmill exercise-SE, invasive coronary angiography, and TTDE-CFVR measurements in the distal segment of LAD during DOB infusion (DOB: 10–40 μg/kg/min). Using quantitative coronary angiography, both minimal luminal diameter (MLD) and percent DS at MB-site at end-systole and end-diastole were determined. Results: Stress-induced myocardial ischemia with the occurrence of WMA was found in 23 patients (28%). CFVR during peak DOB was significantly lower in the SE-positive group compared with the SE-negative group (1.94 ± 0.16 vs. 2.78 ± 0.53; p < 0.001). ROC analyses identified the optimal CFVR cut-off value ≤ 2.1 obtained during high-dose dobutamine (>20 µg/kg/min) for the identification of MB associated with stress-induced WMA, with a sensitivity, specificity, positive and negative predictive value of 96%, 95%, 88%, and 98%, respectively (AUC 0.986; 95% CI: 0.967–1.000; p < 0.001). Multivariate logistic regression analysis revealed that MLD and percent DS, both at end-diastole, were the only independent predictors of ischemic CFVR values ≤2.1 (OR: 0.023; 95% CI: 0.001–0.534; p = 0.019; OR: 1.147; 95% CI: 1.042–1.263; p = 0.005; respectively). Conclusions: Noninvasive CFVR during dobutamine provocation appears to be an additional and important noninvasive tool to determine the functional severity of isolated-MB. A transthoracic CFVR cut-off ≤2.1 measured at a high-dobutamine dose may be adequate for detecting myocardial ischemia in patients with isolated-MB.
Highlights
Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography (TTDE) is a clinically useful and feasible noninvasive diagnostic index for the assessment of fixed coronary stenosis severity [1,2,3,4,5,6,7,8]
The heart rate (HR) ≥50 bpm from baseline was achieved in all patients (100%), whereas the HR ≥75% of maximum age-predicted HR was achieved in 73 patients (90%)
The present study evaluated for the first time the best cut-off value of coronary flow velocity reserve (CFVR) during dobutamine provocation to identify the presence of myocardial ischemia in patients with
Summary
Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography (TTDE) is a clinically useful and feasible noninvasive diagnostic index for the assessment of fixed coronary stenosis severity [1,2,3,4,5,6,7,8]. It has been demonstrated that TTDE-CFVR measured at high-dose dobutamine provides a more accurate functional evaluation of MB compared to adenosine [13]. The purpose of the study was to evaluate the adequate cut-off value of TTDE-CFVR during dobutamine provocation, as compared with exercise-induced myocardial ischemia as reference. It has been shown that coronary flow velocity reserve (CFVR) measurement by transthoracic Doppler echocardiography (TTDE) during dobutamine (DOB) provocation provides a more accurate functional evaluation of myocardial bridging (MB) compared to adenosine. CFVR during peak DOB was significantly lower in the SE-positive group compared with the SE-negative group (1.94 ± 0.16 vs. 2.78 ± 0.53; p < 0.001)
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have