Abstract

This paper is aimed at assessing analytically the dc corona induced pressures in wire-cylinder and wire-plate electrostatic precipitator configurations. This calls for solving the equations describing the corona discharge and the force balance for static gas equilibrium provided that the corona onset voltage and the space-charge-free field values are calculable. The calculated pressure and potential distributions along the gap axis in air and nitrogen at atmospheric pressure agreed well with those measured previously. The calculated corona current density values agreed reasonably with those measured for a high-temperature high-pressure wire-cylinder precipitator. The analytically calculated positive and negative dc corona onset voltages for wire-duct precipitators following proposed criteria based on discharge physics are in good agreement with those measured experimentally at atmospheric and lower pressures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.