Abstract
This paper proposes a coordinated operational strategy of energy storage system (ESS) and wind farm to reduce wind power spillage and alleviate wind power fluctuation. Firstly, power curve of a wind farm, in the form of an equivalent wind turbine, is determined by least square fitting. Based on the power output characteristic of the wind farm and historic operating data, the statistical properties of wind power spillage and fluctuation can be obtained. Secondly, the target for wind farm and ESS power output is calculated. Power generation/absorption capabilities of ESS and available power output reducing range of the wind farm are quantified as well, considering the operational constraints of ESS and dispatched wind power output. Finally, a coordinated operational strategy is developed not only to adjust the combined ESS and wind farm to meet the dispatch requirement, but also to ensure ESS and the wind farm to satisfy operational constraints. Case studies are conducted on a practical wind farm with battery energy storage system installed, which demonstrate that the coordination of ESS can greatly boost the revenue and improve power quality of wind farm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.