The ratio of the collision kerma for ICRU tissue and the air collision kerma in free air was calculated for various phantom depths for broad parallel photon beams of perpendicular incidence on one face of a 30 cm ICRU tissue cube and on the front face of a PMMA slab (front face area 30 cm x 30 cm; thickness 15 cm) using the Monte Carlo method. The calculations were performed for monoenergetic photons in the energy range between 2 keV and 1 MeV. The results, which are also given for a variety of radiation qualities of X ray beams, can be used either as conversion coefficients in calibrating individual dosemeters in terms of dose equivalent quantities defined directly in the phantoms or to calculate correction factors for the determination of ICRU sphere quantities from measurements in phantoms or to calculate correction factors for the determination of ICRU sphere quantities from measurements in phantoms other than the ICRU sphere. Backscatter factors and the conversion coefficients for semi-infinite slab phantoms of the same materials are also given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.