AbstractIn recent years, the use of stimuli‐sensitive interpenetrating polymer network (IPN) hydrogels for the encapsulation and controlled release of protein drugs has received significant attention. The purpose of the present study was to investigate the release of bovine serum albumin (BSA), a model drug, from a series of thermosensitive silk sericin (SS) poly(N‐isopropylacrylamide) and pH‐responsive SS poly(methacrylic acid) IPN hydrogels. The effect of the chemical architecture of the IPN was investigated on the percentage loading of BSA and its subsequent release from the loaded devices. The temperature and pH of the release medium were studied for their impact on the release of BSA. The pulsatile releasing behavior of IPN hydrogels revealed that they can be made into microcapsules or thermo‐valves, which act as an on–off release control. © 2013 Society of Chemical Industry