Abstract

A hollow latex cast of the human larynx and tracheobronchial tree extending to 2 mm diameter airways "inhaled" tantalum powder (mass median aero-dynamic diameter equals 9.2 mum, omicron-g equals 1.41) at 8 liters/min. Tantalum deposited within the cast as predicted by preliminary deposition calculations. These calculations predicted deposition surface densities among greater than 2 mm diam. airways to have a range of similar to 2:1, and also predicted less than 5% alveolar deposition. A deposition surface density of 8 mg/cm-2 provided good bronchographic visualization. Single rice grains located within some airways were distinctly outlined. The small amount of tantalum needed to outline the airways be a simulated voluntary inhalation indicates that tantalum may be suitable for use as a bronchographic contrast medium when administered under strictly controlled exposure conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.