Abstract

In this paper the issue of control strategies for single-stage photovoltaic (PV) inverter is addressed. Two different current controllers (the classical proportional-integral (PI) and the novel proportional-resonant (PR) controllers) have been implemented and an experimental comparison between them has been made. A complete control structure for the singlephase PV system is also presented. The superiority of the PR controller is demonstrated with respect to the PI controller in terms of harmonic current rejection and the capability to remove the steady-state error without using the voltage feedforward (VFF). The control strategy was successfully tested on a real 1.5 kW PV inverter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.