Abstract

Eighteen Toroidal Field (TF) coils are operated on steady-state mode at highest current of 68 kA in comparison with the other pulse operation coils such as Poloidal Field and Central Solenoid coils in ITER superconductive magnet system, which are fed by Coil Power Supply Systema (CPSS). The reliability of TF circuit is significant to investment and nuclear safety of ITER machine. Hence, the comprehensive protection functions as Slow Discharge, Accelerated Discharge and Fast Discharge are required by ITER TF CPSS and the detailed realizations have been illustrated according to the different levels of faults to guarantee the safety of components including TF coils. In addition, the simulation model has been built by MATLAB/SIMULINK according to the real configuration of circuit and control system to verify the protection strategies and the satisfied simulation results have been obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.