Abstract
This study describes the effect of speech rate (fast, 11 syllables per second; medium, 9 syllables per second; slow, 6 syllables per second) on speech perception in 10 cochlear implant users. The speech perception performance was evaluated on the basis of the percentage score of syllables that were correctly recalled in sentences composed of 4 to 6 words. The percentage scores at the fast, medium, and slow speech rates were 15.7%, 39.0%, and 56.0%, respectively. The effect of speech rate slowing was significant (p < .0001). Variations in the effect of speech rate slowing were observed in the cochlear implant users. The improvement of speech perception by speech rate slowing was significantly (p < .005) related to the word test score and the score at the fast speech rate. The results reveal that the rate of speech is an important factor in improving the speech perception of cochlear implant users.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.